Outdoor Fan Speed Control - Panasonic CS-A9KKD Service Manual

Table of Contents

Advertisement

Auto Fan Speed during Heating operation.
Indoor fan will rotate in the range of SLo → Me according to the heat exchanger temperature.
o
(For A9KKD and A12KKD)
12.5.3
Manual Fan Speed Control
Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control.
There are 3 types of fan speed settings: Lo, Me, Hi.
12.5.4
Indoor Fan Motor rpm Abnormal Control
Immediate after the fan motor is started, rpm abnormal control is performed every second.
During fan motor on, if fan motor feedback ≥ 2550 rpm or < 50 rpm continuously for 10 seconds, the fan motor
error counter increased; fan motor is then stopped and restarted. If the fan motor error counter increased to 7,
then air conditioner will stop operation.

12.6 Outdoor Fan Speed Control

There is only one speed for outdoor fan motor. (Applicable for CU-A9KKD and CU-A12KKD)
There is 2 speeds for outdoor fan motor. Outdoor fan speed can be changed to Hi or Lo according to outdoor
temperature. (Applicable for CU-A18KKD, CU-A24KKD and CU-A28KKD).
For Cooling and Soft Dry operation, when outdoor temperature reaches to 31°C (Hi-speed), 29°C (Lo-speed).
(Applicable for CU-A18KKD, CU-A24KKD and CU-A28KKD).
For heating operation, when outdoor temperature reaches to 13.5°C (Hi-speed), 15.5°C (Lo-speed). (Applicable
for CU-A18KKD, CU-A24KKD and CU-A28KKD).
When air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously.
Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.
(For A18KKD, A24KKD and A28KKD)