Fig 3-7 Edit Mode Operation Flow Chart - Prodigit 3350F Series Operation Manual

High power electronic load
Table of Contents

Advertisement

62 PRODIGIT
3.5.4.2 Test Mode
EDIT MODE
FX
SET BANK/STATE
ENTER
SET T1/T2
ENTER
NEXT STEP

Fig 3-7 EDIT MODE OPERATION FLOW CHART

1. Pressing the TEST button will cause the TEST switch to Illuminate and the
LCD to show the last selected Auto-sequence number (F1 to F9).
The numbered STATE buttons (1-9) are used to change the Auto-
Sequence number (F1 ~ F9). Once the desired Auto-sequence has been
Selected press ENTER to start the test.
2. The LCD will display "SXX", where "XX" is the actual STEP being
Presently tested. If during a given test step the values measured are
Outside the preset limits (and the NG Function has been enabled) then
The LCD will flash "NG" And the test is suspended.
The user can press the ENTER button to continue the Remaining test
Steps. Alternatively the EXIT button can be used to leave the test mode.
3. If all the test steps are OK, the LCD displays "PASS". If the Unit under test
Fails any of the test steps the mainframe's LCD will show "FAIL".
If the buzzer is set to ON, the PASS result is also accompanied by a
Single buzzer call out. If the test shows FAIL the buzzer will sound twice.
4. When the test is completed, the user can press the ENTER Key again to
Start the test again. Alternatively the EXIT Button can be used to leave
The test mode.
Press EDIT Key
Press STATE 1~9 Select F1~F9
STORE
END
EXIT