2-3. Fuse Exchange

This product has the power fuse, and exchanges it according to the following procedure.
Never fail to turn off the power of this product, and disconnect the plug of the AC
Power cable.
To avoid the fire or electronic shock, the Fuse that will be used in the product should
have the safety standard in the area of the region you use. Any use of improper Fuse
or shorting the Fuse holder would be extremely dangerous and would be strictly
prohibited.
・ Before exchanging the Fuse, if there are abnormal odor or abnormal noise,
・Please stop using immediately and ask for the repair.
2.3.1. Check the rating of the line fuse and replace it with the correct fuse if necessary.
100V/115V use T2A/250V (5*20mm), 200V/230V use T1A/250V (5*20mm)
2.3.2. The AC line fuse is located below the AC line receptacle see Fig 2-2. Use a small
Screwdriver to extract the fuse holder, to change a new one. Change an appropriate
Specifications fuse which indicated in Table 1-1A.
2.3.3. Reinstall fuse holder and connect the power cord.

Fig 2-2 FUSE RECEPTACLE

3350F Series Operation Manual 13
T2A/250V (5*20mm)
T1A/250V (5*20mm)