5-12. Power Supply SHORT testing
5.12.1. SHORT Manual control
:
Example
5.12.1.1. Setting SHORT test, press Short key to the next step.
5.12.1.2. Press UP key, setting Short time to 10000ms, press Short key to the next Step.
5.12.1.3. Press down key, setting V-Hi voltage to 1.000V, press Short key to the next Step.
5.12.1.4. Press down key, setting V-Lo voltage to 0V, press Short key to the next Step.
5.12.1.5. Press START/STOP test key.
5.12.1.6. Short test finish, the UUT's drop voltage is between V_Hi and V_Lo limitation, then
Middle 5 digits LCD display will shows "PASS"
5.12.1.7. The UUT's not drop voltage is between V_Hi and V_Lo limitation, LCD display will
Shows FAIL.
3350F Series Operation Manual 113