5. It will be shown the Setup Device as the following figure if all steps was corrected to be run.
6. Insert the numbers as the following :
6.1
IP Address: as recommended according to your network
6.2
Subnet Mask: as recommended according to your network
6.3
Gateway Address: as recommended according to your network
6.4
Network link speed: Auto
6.5
DHCP client: Enable
6.6
Socket port of HTTP setup: 80
6.7
Socket port of serial I/O: 4001,TCP Server
6.8
Socket port of digital I/O: 5001,TCP Server
6.9
Destination IP address / socket port (TCP client and UDP) Connection: Auto
6.10 TCP socket inactive timeout(minutes):Set the network disconnection after N minutes,
set 0 minutes will work forever.
6.11
Serial I/O settings (baud rate, parity, data, bits, stop bits): 115200, N, 8, 1
6.12
Interface of serial I/O: RS 232 (RTS/CTS)
6.13
Packet mode of serial input: Disable
6.14
Device ID : 5
6.15
Report device ID when connected:Auto
6.16
Setup password: Not required