5-3. Constant Current mode application

The Constant Current (CC) mode is ideal for testing the Load Regulation, Cross Regulation,
Output Voltage and Dynamic Regulation of the power supply under test. The CC mode can
Also be used to test the Discharge Characteristics and the Life Cycle of cells and battery packs.
In CC operation the 3350F can operate as a static load with switchable high and low current
Levels. It is also possible to operate the load dynamically enabling the user to adjust sink
Current with time.
5.3.1. Static mode: (Fig 5-3)
Major application:
• Voltage source testing.
• Power supply load regulation testing
• Battery discharge testing
V
VOLTAGE
SOURCE
ELECTRONIC LOAD
CC MODE
-
+
DC
INPUT
LOAD CURRENT
SETTING
I
LOAD CURRENT

Fig 5-3 constant mode application