TABLE 1
Table indicating the set frequencies
Number of red lights on
1
2
3
4
5
6
7
8
TABLE 2
Inverter fault code table
Green
= GR
Red
= RD
DISLAY
No.4 green LEDs on,
red LED No.1 on
No.4 green LEDs on,
red LED No.2 on
No.4 green LEDs on,
red LED No.3 on
No.4 green LEDs on,
red LED No.4 on
No.4 green LEDs on,
red LED No.5 on
No.4 green LEDs on,
red LED No.6 on
Output frequency scale [Hz]
18 - 22
22 - 26
26 - 30
30 - 34
34 - 38
38 - 42
42 - 46
46 - 50
FAULT CODE
DESCRIPTION
The internal temperature of the
microcontroller has reached
unacceptable values
The temperature measured by the
heat sink on the NTC sensor has
reached unacceptable values. The
fault status does not remain when
the motorinverter resets and restarts
automatically
The burner power supply voltage has
reached unacceptable values.
The internal power voltage + 15 V DC
of the motorinverter has fallen below
unacceptable values
The electric current in the motor has
exceeded the safety threshold.
The electric current in the motor
has exceeded the safety threshold.
Hardware fault
0006081483_201512
The burner is installed in an environment with
temperature conditions outside the envisaged
limits for proper operation (At > 40°C).
- Unacceptable ambient temperature (At >
70°C).
- Insufficient thermal exchange by the heat sink
(Check that the space between the heat sink
fins is not clogged by dust or dirt)
Power surges in the electrical supply line.
Check that the line is within the values (V=230
-10% +15%)
Inverter board fault. Contact assistance centre
The electric motor has absorbed an higher
amount of current than the amount on its rating
plate, due to an overload for example.
The electric motor has absorbed an higher
amount of current than the amount on its
rating plate, due to the seizure of a bearing
for example.
Inverter board fault, contact Assistance centre