MAINTENANCE TIME
Part description
ELECTRODES
FLAME DISK
IONISATION PROBE
COMBUSTION HEAD
COMPONENTS
INSULATING SEAL
GAS DELIVERY FITTING
GASKET
AIR GRILLE/SHUTTERS
AIR SHUTTER BEARINGS
FAN
AIR PRESSURE SWITCH
AIR PRESSURE PIPES AND
OUTLET
FLAME SENSOR
GAS PRESSURE SWITCH
ELECTRIC MOTORS
MECHANICAL CAM
LEVERS/TIE-RODS/BALL
JOINTS
ELECTRICAL SYSTEM
INVERTER
CO PROBE
O2 PROBE
GAS FILTER
HYDRAULIC/GAS SEALS
CO TEST
CO2 TEST
TEST OF FUMES ACCORDING
TO BACHARACH INDEXES
NOX TEST
IONISATION CURRENT TEST
FUME TEMPERATURE
TESTING
OIL DELIVERY/RETURN
PRESSURE TESTING
GAS PRESSURE REGULATOR
IMPORTANT
In case of heavy use or particular fuels, the maintenance frequency must be increased and adapted to the use conditions according to the
maintenance technician's indications.
COMBUSTION HEAD
VISUAL CHECK, CERAMIC INTEGRITY. END GRINDING, CHECK DISTANCE, CHECK ELECTRICAL
INTEGRITY VISUAL CHECK FOR ANY DEFORMATIONS, CLEANING
VISUAL CHECK, CERAMIC INTEGRITY. END GRINDING, CHECK DISTANCE, CHECK ELECTRICAL
INTEGRITY VISUAL CHECK FOR ANY DEFORMATIONS, CLEANING
VISUAL INSPECTION OF LEAK TIGHTNESS AND POSSIBLE REPLACEMENT
VISUAL INSPECTION OF LEAK TIGHTNESS AND POSSIBLE REPLACEMENT
GREASING, (NOTE: apply only to burners with bearings to be greased)
FAN AND SCROLL CLEANING, DRIVE SHAFT GREASING
SAFETY COMPONENTS
VARIOUS COMPONENTS
COOLING FAN CLEANING, BEARING NOISE CHECK
CHECK OF WEAR AND OPERATION, GREASING OF SLIDING BLOCK AND SCREWS
CHECK OF ANY WEAR, COMPONENT LUBRICATION
CHECK OF CONNECTIONS AND TERMINAL TIGHTENING
COOLING FAN CLEANING AND TERMINAL TIGHTENING
CLEANING AND CALIBRATION
CLEANING AND CALIBRATION
COMBUSTION PARAMETERS
COMPARISON WITH THE VALUES RECORDED UPON THE EQUIPMENT START-UP
COMPARISON WITH THE VALUES RECORDED UPON THE EQUIPMENT START-UP
COMPARISON WITH THE VALUES RECORDED UPON THE EQUIPMENT START-UP
COMPARISON WITH THE VALUES RECORDED UPON THE EQUIPMENT START-UP
COMPARISON WITH THE VALUES RECORDED UPON THE EQUIPMENT START-UP
COMPARISON WITH THE VALUES RECORDED UPON THE EQUIPMENT START-UP
COMPARISON WITH THE VALUES RECORDED UPON THE EQUIPMENT START-UP
PRESSURE MEASUREMENT UPON START-UP
0006081521_201711
Action to be performed
CONNECTION
CONNECTION
AIR LINE
CLEANING
CLEANING
CLEANING
CLEANING
OPERATIONAL TEST
FUEL LINE
REPLACE THE FILTER
CHECK OF ANY LEAKAGES
27 / 34
ENGLISH
Gas
YEARLY
YEARLY
YEARLY
YEARLY
YEARLY
YEARLY
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
YEAR
N.A.
YEAR
YEAR
YEAR