Delta A3000 User Manual page 75

Table of Contents

Advertisement

User Manual
A3000
AC Power Source
Example : [SOURce:]STEP:DWELl?
Parameter : <NR2> effective range:1 ~ 60000.0 (unit:msec)
Parameter returns
[SOURce:]STEP:COUNt
Function : Set (query) how many steps to execute in STEP mode.
Example : [SOURce:]STEP:COUNt?
Parameter : <NR1> effective range:0 ~ 10000
Parameter returns
[SOURce:]SYNThesis
Function : Set (query) which synthesis waveform to use. There are DIS30 and DIS31
Example : [SOURce:]SYNThesis ?
Parameter : DST30 | DST31
[SOURce:]SYNThesis:AMPLitude
Function : Set (query) voltage amplitude for each order of harmonic waveforms.
Example : [SOURce:]SYNThesis:AMPLitude?
Parameter : <NR2>, ..., <NR2>
Effective range
Order
N=2~N=20
N=21~N=30
N=31~N=39
Parameter returns :<NR2>, ...,<NR2>
72
│ www.deltaww.com
[SOURce:]STEP:DWELl 1000.5
:<NR2>
[SOURce:]STEP:COUNt 500
:<NR1>
available.
[SOURce:]SYNThesis DST30
Maximum order is 39.
[SOURce:]SYNThesis:AMPLitude 20.55 33.10 2.55
Gain limit
33.33%
30.00%
15.00%