3.6.3 Inhibit Output by Remote Control Signal(Remote Inhibit)
Remote Inhibit is a「Active HIGH」 TTL signal, high level is 5V, low level is 0V. Its signals
send to 9 pin TTL signal connector (D-SUB) at back panel of the AC source. Please refer
appendix A for pin assignment.
After Remote Inhibit initialized, output control priorities for AC source are as below:
 When both front panel and remote control are idle, output of A3000 SERIES is according
to external TTL ON/OFF signal.
 When user press 「OUT」 from front panel or by remote control, TTL signal has no effect
on the operation.