Delta A3000 User Manual page 72

Table of Contents

Advertisement

User Manual
A3000
AC Power Source
Parameter : <NR2>, ..., <NR2> effective range:30.0 ~ 1000.0 (unit: Hz)
Parameter returns
[SOURce:]LIST:DEGRee
Function : Set (query) start phase angle of 10 individual sequences in LIST mode.
Example : [SOURce:]LIST:DEGRee?
Parameter : <NR2>, ..., <NR2> effective range:0.0 ~ 359.9
Parameter returns
[SOURce:]PULSe:VOLTage:AC
Function : Set (query) AC voltage of PULSE waveform.
Example : [SOURce:]PULSE:VOLTage:AC?
Parameter : <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
[SOURce:]PULSe:FREQuency
Function : Set (query) frequency of PULSE waveform.
Example : [SOURce:]PULSE:FREQuency?
Parameter : <NR2> effective range:30.0 ~ 1000.0 (unit: Hz)
Parameter returns
[SOURce:]PULSe:SPHase
Function : Set (query) start phase angle of PULSE waveform.
Example : [SOURce:]PULSE:SPHase?
Parameter : <NR2> effective range:0.0~ 359.9
Parameter returns
69
│ www.deltaww.com
:<NR2>, ..., <NR2>
[SOURce:]LIST:DEGRee
:<NR2>, ..., <NR2>
[SOURce:]PULSE:VOLTage:AC 250.1
0.0 ~ 300.0 (high voltage range)
:<NR2>
[SOURce:]PULSE:FREQuency 50.0
:<NR2>
[SOURce:]PULSE:SPHase 60.0
:<NR2>
30.6 96.5 88.0 71

Advertisement

Table of Contents
loading

Table of Contents