User Manual
A3000
AC Power Source
2. By rotating knob to change parameter to Vsense, then press
change
3.5.5 Degree On, Off
A3000 SERIES can control the start phase angle (Degree On) or stop phase angle (Degree
Off) of the output voltage waveform. Range for Degree On is 0.0~359.9, and is 0.0~360.0
for Degree Off. When Degree Off parameter is 0, the output stopped immediately no matter
which output status is at. If 0.0 degree for stop phase angle is needed, please set Degree
Off to 360.0.
Following processes demonstrate how to set phase angle Degree On = 100 and Degree Off
= 200:
1. Move cursor to Degree On
2. Change parameter to 100 by numerical key or knob rotating, then press
confirm setting
Save
3. Press
23
│ www.deltaww.com
Save
Recall
Recall
or
to move cursor to Degree Off
to confirm the
Enter
Enter
to