User Manual
A3000
AC Power Source
:COUNt
SYNThesis
:AMPLitude
:PHASe
TRIG
Following are functions, examples and returned parameters for SOURCE command:
[SOURce:]CURRent:LIMit
Function : Set (query) total output rms current limit
Example : [SOURce:]CURRent:LIMit?
Parameter :<NR2>, effective range:0.00 ~ 32.00 (150V range),
Parameter returns
[SOURce:]CURRent:DELay
Function : Set (query) delay time to trigger software over current protection
Example : [SOURce:]CURRent:DELay?
Parameter : <NR2>, Effective range:0.0 ~ 5.0 (unit: sec)
Parameter returns
[SOURce:]CURRent:INRush:STARt
Function : Set (query) time to start measure inrush current
Example : [SOURce:]CURRent:INRush:STARt?
Parameter : <NR2>, effective range:0.0 ~ 1000.0 (unit: msec)
Parameter returns
[SOURce:]CURRent:INRush:INTerval
Function : Set (query) inrush current measurement time
63
│ www.deltaww.com
Set (query) how many steps to be executed in STEP mode
Set (query) which synthesis waveform to use.
Set (query) harmonic voltage amplitude of each order
Set (query) harmonic phase angle of each order
Set Trig events of PULSE, LIST, STEP mode
[SOURce:]CURRent:LIMit 25.5
0.00 ~ 16.00 (300V range)
:<NR2>
[SOURce:]CURRent:DELay 1.2
:<NR2>
[SOURce:]CURRent:INRush:STARt 200.3
:<NR2>

Advertisement