Delta A3000 User Manual page 71

Table of Contents

Advertisement

User Manual
A3000
AC Power Source
Parameter :A|B, ..., A|B
Parameter returns
[SOURce:]LIST:VOLTage:AC: STARt
Function : Set (query) start voltage of 10 individual sequences in LIST mode.
Example : [SOURce:]LIST:VOLTage:AC: STARt?
Parameter : <NR2>, ..., <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
[SOURce:]LIST:VOLTage:AC: END
Function : Set (query) stop voltage of 10 individual sequences in LIST mode.
Example : [SOURce:]LIST:VOLTage:AC: END?
Parameter : <NR2>, ..., <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
[SOURce:]LIST:FREQuency: STARt
Function : Set (query) start frequency of 10 individual sequences in LIST mode.
Example : [SOURce:]LIST:FREQuency: STARt?
Parameter : <NR2>, ..., <NR2> effective Range: 30.0 ~ 1000.0 (unit: Hz)
Parameter returns
[SOURce:]LIST:FREQuency: END
Function : Set (query) start frequency of 10 individual sequences in LIST mode.
Example : [SOURce:]LIST:FREQuency: END?
68
│ www.deltaww.com
:A|B, ..., A|B
[SOURce:]LIST:VOLTage:AC: STARt 110 22.5 55.6
0.0 ~300.0 (high voltage range)
:<NR1>, ..., <NR2>
[SOURce:]LIST:VOLTage:AC: END 1.2 50 66.6
0.0 ~300.0 (high voltage range)
:<NR2>, ..., <NR2>
[SOURce:]LIST:FREQuency: STARt 50.8 80.5 2.2
:<NR2>, ..., <NR2>
[SOURce:]LIST:FREQuency: END 20.5 30.8 77.8