Delta A3000 User Manual page 68

Table of Contents

Advertisement

User Manual
A3000
AC Power Source
Example : [SOURce:]FUNCtion:SHAPe:A:CF?
Parameter :<NR2>,effective range:1.200 ~ 1.414
Parameter returns
[SOURce:]FUNCtion:SHAPe:B
Function :Set (query) waveform of waveform buffer B.
Example :[SOURce:]FUNCtion:SHAPe:B?
Parameter :SINE | CSIN | DST<00~31>
Parameter returns
[SOURce:]FUNCtion:SHAPe:B:CF
Function :Set (query) CF of the cut sin waveform in waveform buffer B. It is effective
Example :[SOURce:]FUNCtion:SHAPe:B:CF?
Parameter :<NR2>,effective range:1.200 ~ 1.414
Parameter returns
[SOURce:]VOLTage:AC
Function :Set (query) output AC voltage
Example :[SOURce:]VOLTage :AC?
Parameter :<NR2>,effective range:0.0 ~ 150.0 (low voltage range), 0.0 ~ 300.0 (high
Parameter returns
[SOURce:]VOLTage:LIMit:AC
Function :Set (query) voltage limit.
Example :[SOURce:]VOLTage:LIMit:AC?
65
│ www.deltaww.com
[SOURce:]FUNCtion:SHAPe:A:CF 1.234
:<NR2>
[SOURce:]FUNCtion:SHAPe:B CSIN
:SINE | CSIN | DST<00~31>
only when CSIN is selected for waveform buffer B.
[SOURce:]FUNCtion:SHAPe:B:CF 1.234
:<NR2>
[SOURce:]VOLTage :AC 200.5
voltage range)
:<NR2>
[SOURce:]VOLTage:LIMit:AC 300.0

Advertisement

Table of Contents
loading

Table of Contents