A3000
AC Power Source
[SOURce:]STEP:DVOLtage:AC
Function : Set (query) voltage change of each step in STEP mode.
Example : [SOURce:]STEP:DVOLtage:AC?
Parameter : <NR2> effective range:-150.0 ~ 150.0(unit:Volt)
Parameter returns
[SOURce:]STEP:FREQuency
Function : Set (query) start frequency for STEP mode
Example : [SOURce:]STEP:FREQuency?
Parameter : <NR2> effective range:30.0 ~ 1000.0 (unit : Hz)
Parameter returns
[SOURce:]STEP:DFRequency
Function : Set (query) frequency change of each step in STEP mode.
Example : [SOURce:]STEP:DFRequency?
Parameter : <NR2> effective range:-150.0 ~ 150.0(unit:Hz)
Parameter returns
[SOURce:]STEP:SPHase
Function : Set(query) start phase angle at STEP mode.
Example : [SOURce:]STEP:SPHase?
Parameter : <NR2> effective range:0.0 ~ 359.9
Parameter returns
[SOURce:]STEP:DWELl
Function : Set (query) output duration time of each step in STEP mode.
71
│ www.deltaww.com
[SOURce:]STEP:DVOLtage:AC 20.5
:<NR2>
[SOURce:]STEP:FREQuency 80.5
:<NR2>
[SOURce:]STEP:DFRequency -10.5
:<NR2>
[SOURce:]STEP:SPHase 80.5
:<NR2>