AC Power Source
[SOURce:]PULSe:COUNt
Function : Set (query) how many times to execute PULSE voltage.
Example : [SOURce:]PULSE:COUNt?
Parameter : <NR1> effective range:0 ~ 10000
Parameter returns
[SOURce:]PULSe:DCYCle
Function : Set (query) execution time of PULSE waveform, it must be no longer than
Example : [SOURce:]PULSE:DCYCle?
Parameter : <NR1>, effective range:1 ~ 59999 (unit: msec)
Parameter returns
[SOURce:]PULSe:PERiod
Function : Set (query) total period of PULSE mode
Example : [SOURce:]PULSE:PERiod?
Parameter : <NR1> effective range:2 ~ 60000 (unit: msec)
Parameter returns
[SOURce:]STEP:VOLTage:AC
Function : Set (query) start voltage for STEP mode.
Example : [SOURce:]STEP:VOLTage:AC?
Parameter : <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
70
│ www.deltaww.com
[SOURce:]PULSE:COUNt 500
:<NR1>
total period in PULSE mode.
[SOURce:]PULSE:DCYCle 300
:<NR1>
[SOURce:]PULSE:PERiod 600
:<NR1>
[SOURce:]STEP:VOLTage:AC 150.5
0.0 ~ 300.0 (high voltage range)
:<NR2>