ED5000N (S)(A) Series Exit Device
Typlcal ED5000N (S)(A) M802 Series Lock Application Diagram (24VDC Lock)
Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)
Reader Electronics Require 12 or 24VDC UL294 Listed, Power Limited Power Supply (or UL603)
12 Conductor
ElectroLynx
From McKinney
5) Wiring Diagrams (Continued)
MODE 1: LED WIRE NOT USED = RED LED 'ON' WHEN POWERED
QC12
Electric
Hinge
From
Harness
McKinney
24VDC Lock
Body Power
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
LED - Yellow, 8
Not Used
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
H
N
G
120 VAC
24 VDC
Input
-
+
Power Supply
(By Others)
6
ULC-S319 compliance:
EAC power supply utilizing battery backup (30
minutes operation) is required.
Electrical Access
(-)
Control Panel
12VDC
(+)
(By Others)
DATA 1
DATA 0
RX
RX
Use (NC) for Fail
Safe Operation
Lock Relay**
DPS
(NO) Fail
DPS
Secure
Operation
**To prevent inductive "kickback"
on solenoid-operated lockset,
Access 600 Reader
use of 'flyback' diode is required
Electronics
(1N4001, 1N5400 suggested)
Require 12 or 24VDC
UL294 Listed, Power
Limited Power Supply
(or UL603)
Copyright © 2018 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.