Please note the following criteria when choosing a location for the inverter:
ments regarding
choice of loca-
Install only on a solid, non-flammable surface
tion
If the inverter is installed in a switch cabinet or a similar sealed area, then
forced-air ventilation must be provided to ensure adequate heat dissipation.
If the inverter is to be installed on the outer wall of a cattle shed, maintain a
minimum all-round clearance of 2 m between the inverter and all ventilation
and other openings in the building.
The installation location must not be exposed to ammonia, corrosive vapours,
salts or acids.
Do not install the inverter on a vertical wall or pillar with its con-
nection sockets facing upwards.
Do not install the inverter overhanging with the connection sock-
ets at the top.
Do not install the inverter overhanging with the connection sock-
ets at the bottom.
Do not install the inverter on the ceiling.
Max. ambient temperatures:
-40 °C / +60 °C
Relative humidity:
0-100%
The airflow within the inverter is
from the right to the top (cold air
taken in from the right, hot air dis-
sipated out of the top).
The exhaust air can reach a temper-
ature of 70 °C.