Internal schem-
On the V+/GND pin, it is possible to feed in a voltage of around 12.5 - 24 V (+ max. 20%)
atic connection
with an external power supply. The outputs IO 0 - 5 can then be operated with the
diagram of the
external voltage. A maximum of 1 A can be drawn per output, with a maximum of 3 A
IOs
allowed in total. The fuse protection must be located externally.
Risk of polarity reversal at the terminals due to improper connection of external
power supplies.
This may result in severe damage to the inverter.
IMPORTANT!
If the total output (6 W) is exceeded, the inverter switches off the entire external power
supply.
(1)
CAUTION!
Check the polarity of the external power supply with a suitable measuring device
before connecting it.
Connect the cables to the V+/GND outputs with the correct polarity.
Power limitation
Push-in terminal for the WSD installa-
tion. See chapter
WSD (wired shut-
down)" on page 56.
Power supply max. 1 A at 5 V. Software
updates and data recording via USB is
not possible.
Push-in terminal for digital inputs/
outputs. See chapter
Permitted cables
for the data communication area
page 53.
The designations (RG0, CL0, 1/5, 2/6,
3/7, 4/8) on the terminal refer to the
Demand Response Mode function, see
chapter
"PSC editor - AUS - Demand
Response Modes (DRM)"
63.
on
on page
21