10. Turn the display cover clockwise until it is fully seated.
11. Replace the end-cap clamp by tightening the cap screw.
12. Restore power to the transmitter.
3.7 Rotate the sensor wiring junction box on a remote-
mount transmitter (optional)
In remote-mount installations, you can rotate the sensor wiring junction box on the transmitter plus or minus
180º.
Procedure
1. Using a 4 mm hex key, loosen and remove the clamp securing the sensor wiring junction box in place.
Figure 3-16: Removal of the clamp
2. Gently rotate the junction box to the desired position.
You can rotate the junction box plus or minus 180º to any position.
Figure 3-17: Rotation of the sensor wiring junction box
3. Gently set the junction box into its new position, confirming that the position is locked.
4. Replace the clamp in its original position and tighten the cap screw. Torque to 28 in lbf (3.16 N m) to
30 in lbf (3.39 N m).