Mounting and sensor wiring
4.
5.
6.
7.
8.
9.
10.
11.
12.
2.7
Rotate the sensor wiring junction box on a
remote-mount transmitter (optional)
In remote-mount installations, you can rotate the sensor wiring junction box on the
transmitter plus or minus 180º.
1.
24
Carefully loosen the semi-captive display screws while holding the display module in
place.
Carefully pull the display module out of the main enclosure.
Rotate the display module to the desired position.
Gently press the display module back onto the connector.
Tighten display screws.
Place the display cover onto the main enclosure.
Turn the display cover clockwise until it is fully seated.
Replace the end-cap clamp by tightening the cap screw.
Restore power to the transmitter.
Using a 4 mm hex key, loosen and remove the clamp securing the sensor wiring
junction box in place.
Micro Motion
®
Model 5700 Ethernet transmitters