USC LPV100 Operator's Manual page 38

Seed treater for loss-in-weight treaters
Table of Contents

Advertisement

1. Remove and clean the atomizer
housing.
2. Remove the atomizer head and
stainless steel plumbing. The
atomizer head may be disassembled
(right), for easier cleaning.
It is threaded together and can simply
be unscrewed.
3. Reinstall the atomizer head and
plumbing. Grease the bearing and
spin the atomizer head a few times
to ensure all grease has been worked
into the bearings.
1. Remove the shields and clean out any seed that may have fallen
underneath the drum.
2. Clean out any residue left on the inside of the drum and around the seed
lifters.
3. Lubricate the chain to keep from corroding in storage.
1. Disconnect power to the machine.
2. Store the machine inside a protective building to keep it from being exposed to the
weather.
3. Ensure all guards and safety labels are in place.
Page 38
TD-09-06-1064 LPV 100 SEED TREATER
ATOMIZER CHAMBER
ROTATING DRUM
FINAL
REFER
TO
PAGE 5
REFER
TO
PAGE 5