USC LPV100 Operator's Manual page 20

Seed treater for loss-in-weight treaters
Table of Contents

Advertisement

chain. Connect the two red plugs onto each of the remaining open PJESTOP con-
nectors on the first and last panel.
9. Connect cable from actuator communications on LIW gate located on either the
box dump hopper, or batch hopper with LIW gate.
10. Connect up to 4 auxiliary devices such as Dry Additive Feeder, manual pump
stands, etc.
11. Connect the flow meters from up to 4 pump stands.
12. Connect cable from actuator power on LIW gate located on either the box dump
hopper, or batch hopper with LIW gate.
13. Connected to drum motor. Prewired at the manufacturing plant
14. Connected to atomizer motor. Prewired at the manufacturing plant.
15. Connect pump motors.
16. Connect yellow cable from to the drum tilt actuator box to the drum tilt actuator un-
der the treater. Note: the yellow cable is attached to the actuator box at the manu-
facturing plant.
DRUM TILT ACTUATOR
Page 20
TD-09-06-1064 LPV 100 SEED TREATER
LPV TREATER CONNECTIONS
16
17
16