USC LPV100 Operator's Manual page 29

Seed treater for loss-in-weight treaters
Table of Contents

Advertisement

STEP 1: Verify power is suppled to the LPV manual drum tilt panel. The panel is rated
for 120/240V 1PH Power. The panel under normal operation has a full load amp draw
of 2.5 amps at 120 volts and 1.3 amps at 240 volts.
STEP 2: Verify the drum tilt cable is connected to the drum tilt actuator. The actuator
is located underneath the treaters drum near the discharge end. Before operating the
drum tilt, verify the treaters drum path is clear of all obstructions and that the actuator
moves freely.
STEP 3: Turn the UP / OFF / DOWN switch to the indicated position to change the
treater drum tilt elevation. The switch is a spring return to center, and when released
the switch will return to the OFF position. UP (turn switch to the left position) will raise
the treaters drum at the discharge end. DOWN (turn switch to the right position) will
lower the treaters drum at the discharge end. OFF (center position) will stop any further
elevation changes.
1
TD-09-06-1064 LPV 100 SEED TREATER
DRUM TILT OPERATING INSTRUCTIONS
3
2
Page 29

Advertisement

Table of Contents
loading

Table of Contents