1. USB Port.
2. Connect any MODBUS equipment to one of these three.
3. Connected to the proximity switch located in the inlet hopper. This is only used
when an inlet conveyor is feeding the treater.
4. Connect cable from proximity switch located above the slide gate on the LIW gate.
5. Connect cable from load cell summing box, located on either the box stand above
the treater, or batch hopper with LIW gate.
6. Connect inlet conveyor.
7. Connect outlet conveyor.
8. Connect the red cable to the PJESTOPA on the Main Control Panel (MCP) and
then to the PJESTOPB on the next panel that is closest to the MCP. Repeat this
process until all control panels are connected in a daisy chain configuration. It may
be other items of equipment with similar connections. The order or number of devic-
es is not important. It is important that each cable is ran from an A connection to a
B connection (never A to A or B to B), and that no control panel is left out of the
TD-09-06-1064 LPV 100 SEED TREATER