8 . F a u l t D i s p l a y s

8.1 Wireless Mismatch

If an input is assigned as a type (Final exit, Intruder, etc) but no
wireless detector has not been learnt on that input number or vice
versa, this fault will be displayed.

8.2 Wireless Tamper

If a wireless input is in tamper, the alarm will activate and the input
in fault will be displayed.

8.3 Battery Low

The Enforcer 32-WE monitors the batteries of each wireless device and is defined by the following
displays:
Battery Low UXX (U = Keyfobs. XX = User Number)
Battery Low IXX (I = Inputs. XX = Input Number)
Battery Low BXX (B = Bell. XX = Bell Number)
If battery low is displayed it is advisable to replace the battery within 28 days of this message being
shown.

8.4 Wireless Supervision

The Enforcer 32-WE monitors the operation of each wireless device
and is defined by the following:
Radio Supervision IXX (I = Input, XX = Input Number)
Radio Supervision BXX (B = Bell, XX = Bell Number)
If this occurs it would be advisable to check the signal strength of the device in the diagnostics
function.

8.5 Jamming

This is reported when a jamming signal is recognised on the
wireless frequency.
Check that no wireless interference is in close proximity to the radio
devices/panel.

8.6 Wireless Poll Fault

This is displayed when no 'polls' are received for 20 minutes before
the set operation. Test the signal strength / battery on each
wireless device.
Enforcer 32-WE Wireless Setup Manual
Page: 13
Wirls mismatch
Input 01
Alarm Silenced
Input 01
User
Battery Low V05
Input 02
Wirls Supervn F1
Office
Wireles Jam WZm
Input 01
Wirls Poll F700