Keyfob on
If 'Yes' allows use of the wireless keyfob to disarm the system only when the Entry
Entry
Door has been opened and entry time has started.
Wireless Bell
The wireless bell has its own wireless supervision detection in addition to the general
Supervision
wireless supervision used on all wireless accessories including the bell. If 'Yes' then the
wireless bell own supervision feature will be activated.
Download if
If enabled, downloading from the InSite software to the panel is possible regardless of
Armed
if the PCX is armed or not. If disabled, downloading will only be possible when the PCX
is disarmed.
6 Digit Codes
All codes can either be 4,5 or 6 digits. If this option is enabled, all codes must be 6
digits.

5.13 System Displays

Please see page 4 for the 'Text Programming' section as this function involves programming different
text for the PCX system.
System
Description
Displays
Area Texts
You may choose how you want each area to be displayed, i.e. "Area A" may be used to
fully arm a house therefore you may want to call it "Full House Arm" for example. You
can have a maximum of 16 characters on the display.
Full Area
This is the text that can be displayed if all the areas on the system are armed.
Text
Top Display
The top display text is shown on the keypad in disarmed mode.
Text
Site Name
The Site Name is used as a "Site Reference" which if used must be also used within
the PCX 46 Upload/Download Software in order for the software to connect to the PCX
system.
NOTE: The Site Name acts as an additional UDL password so, when set up a site
name make sure it is the same in the UDL otherwise a connection will not be possible.
Display If
If programmed as 'yes' then the PCX keypad will display on the keypads when the
Armed
system is armed. Program 'No' to ensure compliance with EN 50131.
Display
If programmed as 'yes' then the system will display on the keypads any alarms
Alarms
without requiring user to enter their code or tag. Program 'No' to ensure compliance
with EN 50131.
Ready LED
If programmed as 'enabled', the 'OK' LED will illuminate whilst the panel is disarmed
ON
and when all the inputs in the areas (that the keypad controls) are closed. Program
'No' to ensure compliance with EN 50131.
Display PAs
If programmed as 'yes' then the system will display on the keypads any PA alarms
without requiring the user to enter their code or tag. Leave at 'No' to ensure
compliance with EN 50131.
Display
If programmed as 'yes' then the system will display on the keypads any silent PA
Silent PAs
alarms without requiring the user to enter their code or tag. Leave at 'No' to ensure
compliance with EN 50131.
Display
If programmed as 'enabled', any inputs activated in disarmed mode will be displayed.
Inputs
Program 'No' to ensure compliance with EN 50131.
Disarm LED
If programmed as 'enabled', the disarm LED (green) will illuminate continuously whilst
ON
the system is in the disarmed state. Program 'No' to ensure compliance with EN
50131.