Battery Status - Pyronix Enforcer 32-WE Wireless Setup Manual

Security grade 2, environmental class ii
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

6.2 Battery Status

The diagnostics function also monitors the battery
of each of input and bell so that any batteries that
need replacing can be easily identified.
The Enforcer 32-WE has an advanced battery test
mechanism that operates by monitoring all
inputs/bells after 5 minutes from the start of the
test. It will perform this test every 16 seconds.
Once the function is entered, a count down from
300 will begin. Press  to go to the main display,
one of the following will be displayed:
Testing = Waiting for a battery result
Good = At least one month of battery life
remaining
Replace = Battery needs to be replaced
immediately
Enforcer 32-WE Wireless Setup Manual
Page: 11
Battery Status Procedure.
Bell
No Signal
Press 
Battery?
Press 
Inputs?
Press 
Please Wait
300
Press 
Input
Good
Use [ or ]. Press 
Bells?
Press 
Bell
Good
Press 
Input
Excellent
Press 
[1]
[000]
[01]
[1]
[01]
[100]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wireless kf4-we

Table of Contents