Figure 31: Enclosure Power and Data Connections
a. Connect the Ethernet cable to the Ethernet management port.
b. Connect the power cables into each of the PSUs at the rear of the unit. The BMC Module,
PSUs, and Fan Modules should all power on.
c. Verify the LEDs are illuminated on the PSUs.
d. Tighten the cable retention clips by sliding each one forward on the PSU until it stops near
the cable connector. Doing this will ensure that the retention clip functions properly in the
event the cable is pulled on.
Figure 32: Cable Retention Clip Operation
Step 5 : Once the enclosure has been powered on, the E3000 will use DHCP to establish an IP address.
The default hostname set during this process will be
Use the MAC address that was recorded earlier in step
hostname of the BMC Module:
Example MAC Address:
Resulting Hostname (based on MAC address):
00:0C:CA:09:00:33
e3000-090033
1.5 Chassis Installation
e3000-{last-3-bytes-of-MAC-address}
3.c (page 18)
to determine the default
1. Installation
.