Interfaces - ELGO Electronic EMAX-HI Series Operating Manual

Magnetic absolute length measuring system
Table of Contents

Advertisement

6.4

Interfaces

6.4.1
SSI (Interface Option SB0 and SG0)
If the clock is not interrupted for the time Tm-T/2 (output of further 25 periods), the shift register clocks once
again the same data value (error recognition in evaluation).
Some encoders contain a Power Failure Bit (PFB):
With EMAX-HI the PFB is always „low".
Figure6 Interface SSI
Figure 6: Interface SSI
6.4.2
CANopen (Interface Option CA0)
When ordering option CA0, the EMAX-HI measuring system is equipped with a CAN interface
according to CANopen standard DS406.
The following identifiers are given:
CAN - Identifier
(4 Byte telegram)
181 (16)
4 bytes
Baud rate
LSB
xxh
xxh
xxh
ABS-Position
Figure 7: Interface CAN
Available CAN options and further information about the DS406 device profile can be found in the down-
loadable XDD file. Download link:
Not inverted SSI-Clock
= Identifier with device address 1
= Position
= depends on order information ( 9 Type designation)
MSB
xxh
https://www.elgo.de/fileadmin/user_upload/software/EMAXHI_DS406.zip
- 17 -
Connections and Interfaces