Technical Data Sensor - ELGO Electronic EMAX-HI Series Operating Manual

Magnetic absolute length measuring system
Table of Contents

Advertisement

4.3

Technical Data Sensor

EMAX-HI (standard version)
Mechanical Data
Measuring principle
Repeat accuracy
System accuracy in at 20° C
Distance sensor - magnetic tape
Basic pole pitch
Sensor housing material
Sensor housing dimensions
Necessary type
Maximum measuring length
Connections
Sensor cable
Weight
Electrical Data
Supply voltage
Residual ripple
Power input
Interfaces
Resolution
Speed
Conditions
Storage temperature
Operation temperature
Relative humidity
Air pressure (storage/transport)
Air pressure (operation)
Protection class
absolute
±1 Increment
±(10 µm + 20 µm x L[m])
L = measuring length in meters
max. 0.5 mm (without covering tape)
1 mm
aluminium
L x W x H = 70 x 16 x 30 mm
AB20-10-10-2-R-11
8 m
circular plug 12-pin M12 outboard
5 m standard cable length (others upon request)
approx. 50 g without cable; cable approx. 60 g/m (accessories)
10 ... 30 VDC
10 ... 30 VDC < 10%
max. 150 mA
standard: SSI-Interface or CANopen
on request: CAN BASIC ELGO or BISS-C
0.001 mm
1 m/s at permanent absolute position readout
10 m/s at SC10 readout
2 m/s at TTL square wave readout
-20 ... +85° C
-10 ... +70° C
(-20 ... +75° C upon request)
max. 95 %, non-condensing
700 ... 1060 hPa
750 ... 1060 hPa
IP50 (standard)
IP65 (option V)
higher protection class on request
- 9 -
Technical Data

Advertisement

Table of Contents
loading

Table of Contents