Description Installation / Installation Of The Indicator - ELGO Electronic EMAX-HI Series Operating Manual

Magnetic absolute length measuring system
Table of Contents

Advertisement

5.2

Description installation / Installation of the indicator

5.2.1
Mounting Tolerance
NOTE!
Pay attention to correct distance sensor / magnetic tape 0,1 mm...max. 0,5 mm! The LED-
Indicator on the sensor housing flashs red, if this distance is exceeded.
The direction arrow have to point in the same direction by the assembly.
Notice by the installation of the system the compliance of the given tolerance! Outside these
areas the function is not guaranteed!
Install the sensor with M3 screws, see chapter "Dimensions of sensor".
Table 1: Mounting Tolerances
Tolerances
Magnetic tape type
Ride height
Pitch
Yaw angle
Roll
Lateral offset
Ride height
Pitch
<±1,0°
Figure 3: Mounting Tolerances
AB20-10-10-2-R-11
0.1 mm...max. 0.5 mm (without cover band )
0.02 mm...max. 0.2 mm (with cover band)
max. distance 0.5 mm must not be exceeded at any position
<±1 °
max. distance 0.5 mm must not be exceeded at any position
±0.5 mm
Sensorabstand
Längsneigung
Gierwinkel
Yaw angle
Roll
Seitenneigung
0.1 – 0.5 mm without
cover tape
0.02 – 0.2 mm with
cover tape
Lateral offset
Seitenversatz
±0,5mm
- 12 -