Wiring guidelines

The Mio Modero requires 12 VDC power to operate properly. The necessary power is supplied via the
AxLink cable. The maximum AxLink wiring distance is determined by power consumption, supplied
voltage, and the wire gauge used for the cable. The following table lists wire sizes and the maximum
lengths allowable based on the maximum power consumption rating of 170 mA.
Wiring Guidelines at 170 mA
Wire
Size
18 AWG
20 AWG
22 AWG
24 AWG
The maximum wiring lengths for using AxLink power are based on a minimum of 13.5 volts available.

Connecting the Wiring

The following paragraphs describe wiring connections for using the AxLink and relay connectors.
If using power from AxLink, disconnect the wiring from the control system before
wiring the Mio Modero.

AxLink Data and Power Connections

Connect the control system's AxLink connector to the AxLink connector on the rear panel of the Mio
Modero for data and 12 VDC power as shown in FIG. 6.
PWR +
AXP
AXM
GND -
Mio Modero
FIG. 6
AxLink straight-thru wiring
Mio Modero Device Family
Maximum Wiring
Length
690.42 feet (210.43 m)
436.80 feet (133.13 m)
272.33 feet (83.00 m)
171.66 feet (52.32 m)
Installation
PWR +
AXP
AXM
GND -
Control System