■ Error code 0D00
Storage Full
There is no space in the Memory.
Unable to save data because there is no space in the storage data area of memory.
<User Check>
- Delete the data of secure print, personal print, or public print that is stored in the machine.
Step
1
Malfunction of USB storage
memory
2
USB storage memory failure
3
Main PCB failure
■ Error code 0D01
Storage Error.
To use other functions, press GO. Refer to the User's Guide for instructions
on correcting the Storage Error.
Failed to read/write data in the storage I/O.
<User Check>
- Turn OFF and ON the power switch.
- Delete error indication by the following procedure.
(1) Press the Menu button at ready state.
(2) Press the
button three times to select the "General Set Up" and press the OK button.
(3) Press the
button nine times to select the "Macro / Font" and press the OK button.
(4) Press the
button and Cancel button at the same time. * "Format Stage" is displayed.
* When pressing the
machine operates even by pressing the Cancel button soon after pressing the
(5) Press the 1 button. "Format OK?" is displayed on the LCD.
(6) Press the 1 button again. "Formatting" is displayed on the LCD and error is cancelled.
Step
1
USB storage memory failure
2
Main PCB failure
Cause
button and Cancel button at the same time does not work the
Cause
2-37
Remedy
Format the USB storage memory.
Replace the USB storage memory.
Replace the main PCB ASSY.
Remedy
Replace the USB storage memory.
Replace the main PCB ASSY.
button.