Adjustment of the height of the glass face at platen cap position
(1) Press the 3 and 1 buttons in this order in the initial state of the maintenance mode.
"1.CAP PRSR CHK" is displayed on the LCD.
(2) Press the
or
button. "PLATEN ADJ:00" is displayed on the LCD.
(3) Enter a 2-digit adjustment value from the ten-key keypad and press the OK button.
(The range of the adjustment values is 00 to 30.)
(4) Save the adjustment value and returns to the initial state of the maintenance mode.
Water pump operation check
(1) Press the 3 and 1 buttons in this order in the initial state of the maintenance mode.
"1.CAP PRSR CHK" is displayed on the LCD.
(2) Press the
or
button. "MOTOR LOCK OK" is displayed on the LCD, and the Water pump operation
starts.
(3) After checking the operation, press the Cancel button. The machine returns to the initial
state of the maintenance mode.
Adjustment of the height of the glass face at platen wipe position
(1) Press the 3 and 1 buttons in this order in the initial state of the maintenance mode.
"1.CAP PRSR CHK" is displayed on the LCD.
(2) Press the
or
button. "PLATEN WP-ADJ:16" is displayed on the LCD.
(3) Enter a 2-digit adjustment value from the ten-key keypad and press the OK button.
(The range of the adjustment values is 00 to 22.)
(4) Save the adjustment value and returns to the initial state of the maintenance mode.
Adjustment of rib-platen height
(1) Press the 3 and 1 buttons in this order in the initial state of the maintenance mode.
"1.CAP PRSR CHK" is displayed on the LCD.
(2) Press the
or
button. "RIBPLATEN ADJ:14" is displayed on the LCD.
(3) Enter a 2-digit adjustment value from the ten-key keypad and press the OK button.
(The range of the adjustment values is 00 to 28.)
(4) Save the adjustment value and returns to the initial state of the maintenance mode.
button to display "6.PLATEN ADJ" on the LCD and press the OK
button to display "7.HUMID MTR CHK" on the LCD and press the OK
button to display "8.PLATEN WP-ADJ" on the LCD and press the OK
button to display "9.RIBPLATEN ADJ" on the LCD and press the OK