Only use tool holders in the intended admissible speed range.
Tool holders may only be modified in compliance with the recommendation of OPTIMUM
or the clamping device manufacturer.
3.8

Electrical connection

CAUTION!
Arrange the machine's connection cable in such a way that it will not cause a tripping
hazard.
Please verify if the type of current, voltage and protection fuse correspond to the values speci-
fied. A protective earth ground wire connection must be available.
Main Fuse 16A.
Overview of the EMC categories:
Categorie C1
required limit values Class B Group 1 according to EN 55011
Categorie C2
Required limit values class A Group 1 according to EN 55011, Installation by EMC experts
and warning: "This is a product of category C2 according to EN 61800-3. This product may
cause radio interference in a residential area. In this case, it may be necessary for the ope-
rator to take appropriate action."
Categorie C3
Required limit values class A group 2 according to EN 55011, whereby these limit values
are below those of class A group 1, plus warning: „This type is not suitable for connection to
a public low-voltage network supplying residential buildings. When connecting to a public
low voltage network, radio frequency interference is expected. "
MH22V
Categorie
Environment
Voltage / Current
EMC knowledge
MH22VD
Categorie
Environment
Voltage / Current
EMC knowledge
Version 1.0.4 - 2020-07-28
C1
C2
Residential area
Business area
Industrial area
< 1000 V
no requirement
Installation and commissioning by an EMC expert
C1
C2
Residential area
Business area
Industrial area
< 1000 V
no requirement
Installation and commissioning by an EMC expert
Translation of original instruction
C3
C4
Industrial area
> 1000 V
C3
C4
Industrial area
> 1000 V
MH22V│MH22VD