Code
Error Name
1126
CR lock set error
Capping Unit operation in abnormal.
CR lock set release error
1127
Overcurrent error
The electric current flowing in the CR Unit exceeds the expected
amount.
1138
CR Motor over current
1.
Connection failure of the CR Motor or the CR encoder sensor.
error
2.
Detects accumulatively more than the specified number of times
that the electric current which flows when driving the CR Motor
is irregularly large.
1139
Oscillation error
The direction of the electric current flowing in the CR Motor repeats
reversing in the set frequency.
113A
CR Motor overload error The electric current flowing when driving the CR Motor is
irregularly large.
DX100 Service Manual
Table 3-5. Troubleshooting by Error Code
Cause
• Motor failure
• Cable is damaged.
• Board is damaged.
• Capping Unit failure
• Irregular load due to paper jam.
• Motor Lock
• Motor driver failure
• Encoder sensor failure
• Irregular load
• Sensor failure
• Motor driver failure
• Encoder sensor failure
• Motor failure
• FFC of the sensor was failure
• CR Motor cable is damaged.
• Irregular load
• Encoder sensor failure
• Motor failure
Check Item
1.
Check the connection between the Capping Unit and Main
Board (CN203).
2.
Unlock the CR Lock and check if the CR Lock functions
normally.
(P. 242)
Check if there are any foreign objects in the path of the CR Unit.
1.
Check the connection between the CR encoder sensor and Main
Board (CN100).
2.
Check the connection between the CR Motor and Main Board
(CN200).
Check if there are any foreign objects (such as a clip) that may
cause a short circuit around the motor driver on the Main Board.
Check if the CR encoder sensor is broken.
1.
Check if the CR Unit is installed correctly.
2.
Check if there are any foreign objects on the drive section of the
CR Unit.
3.
Check the connection between the CR encoder sensor and Main
Board (CN100).
4.
Check the connection between the CR Motor and Main Board
(CN200).
5.
Carry out "Motor Measurement Adjustment" to check if the CR
Motor functions normally.
(P. 270)
3.4Troubleshooting by Error code
Remedy
1.
Replace the Capping Unit with a new one.
(P. 182)
2.
Replace the Main Board with a new one.
(P. 107)
Remove the foreign objects in the path if
any.
Error reoccurs
• Replace the CR Motor with a new
one.
(P. 196)
• Replace the Main Board with a new
one.
(P. 107)
• Replace the CR Unit with a new one.
(P. 124)
1.
Replace the CR Unit with a new one.
(P. 124)
2.
Replace the CR Motor with a new one.
(P. 196)
3.
Replace the Printer with a new one.
Remove the foreign objects on the board if
any.
Error reoccurs
• Replace the Main Board with a new
one.
(P. 107)
• Replace the CR Unit with a new one.
(P. 124)
• Replace the CR Motor with a new
one.
(P. 196)
1.
Reinstall the CR Unit.
(P. 124)
2.
Replace the CR Unit with a new one.
(P. 124)
3.
Replace the CR Motor with a new one.
(P. 196)
60