4.5.4.4 CR Scale

Take care not to bend the CR Scale when removing/installing it
C A U T I O N
because it is fragile.
When handling the CR Scale, make sure to hold the scale only by the
edges taking care not to touch the scale surface.
Never touch the scale surfaces. Be extremely careful not to
contaminate or scratch the scale surfaces.
1.
Remove the Top Cover.
(P.97)
2.
Remove the Upper Cover.
(P.100)
3.
Remove the Rear Frame.
(P.101)
4.
Move the CR Unit to the center.
5.
Remove the torsion spring from CR Scale.
6.
Disengage the CR Scale from the hook of the frame at left side of the printer, and Pull
out the CR Scale slowly from the CR Unit.
7.
Pull out the CR Scale slowly from the slit of the carriage assembly, and then turn the
scale 90 degrees upward and remove it from the hook of the frame.
Attach the CR Scale so that its notched portion facing upward. (See
Figure
4-51)
Make sure not to let the CR Scale touches the CR Unit when inserting
the CR Scale into the slit of the CR Unit.
DX100 Service Manual
CR Unit
Slit
4.5Disassembly and Assembly Procedure
Left
Hook
Figure 4-51. Removing the CR Scale
CR Scale
CR Unit
Right
Torsion spring
Hook
Chipped portion
123