Download Print this page

EAS Electric EDM Series Owner's Manual page 113

Middle static pressure duct type
Hide thumbs Also See for EDM Series:

Advertisement

Available languages

Available languages

The design and specifications are subject to change without prior notice for product
improvement. Consult with the sales agency or manufacturer for details.
Connections electronic board indoor unit model 35 and 52
16023000008781 WIRING DIAGRAM
FOR ANTI-COLD WIND
ON
ON
SW1
1 2
1 2
TEL0
24℃
15℃
FACTORY
SETTING
FOR SETTING FAN MOTOR CONTROL
WHEN THERE IS NO DEMAND
ON
SW2
1
M O D E
FAN OFF
FACTORY SETTING
F F O O R S
R SE E T T T T I I N N G G A A U U T T O O - - R R E E S S T T A A R R T T
ON
SW3
1
MODE
AUTO-RESTART NOT AUTO-RESTART
FACTORY SETTING
FOR TEMP. COMPENSATION(HEATING)
ON
ON
SW6
1 2
1 2
CODE
6℃
2℃
FACTORY
SETTING
FOR SETTING NETADDRESS
0
S1+S2
8
CODE
0~F
0~15
NETADDRESS
F A C T O R Y S E T T I N G
V.1
(It comes from page 22)
M
ON
ON
1 2
1 2
DC FAN
EEPROM
8 ℃
DEFAULT
ON
1
AC FAN
FAN ON
Y/G
5
M
WHITE
WHITE
(GRAY)
ON
1
CAP
FOR SETTING POWER
0
0
ON
ON
ENC1
8
8
1 2
1 2
CODE
0
1
EEPROM
4℃
DEFAULT
POWER
20
26
F A C T O R Y
ACCORDING TO RELATED MODEL.
S E T T I N G
0
0
0
ON
ON
ON
1 2
1 2
8
1 2
8
8
0~F
0~F
0~F
16~31
32~47
48~63
140 mm
3
3
FAN FOR THE
FRESH AIR
OR ANION
FAN1
GENERATOR
RED
DC MOTOR
CON2
DRIVER MODLE
RED
CN1
CON1
REACTOR
4
3
ALARM
CN34 CN15
CN43
3
CN4
P2
BROWN
P1
BLACK
INDOOR UNIT
MAINBOARD
0
8
CN9
CN45
2
CN40
32~35
X
Y
HB HA
4
ON
1 2
To CCM
Comm.Bus
35
NOTE:
1.
The parts with dotted line indicates
Alarm
Remote
Output
Control
optional features.
2.
Remove the short connector of J7
when you use the "on-off" function.
ON/OFF
J7
CN33
CN23
PUMP
2
M
CN13
MAGNETIC RING
10
5
DISPLAY
WIRE
CN10
BOARD
CONTROLLER
Y/G
4
CN6
INDOOR COIL TEMP. SENSOR
ROOM TEMP. SENSOR
CN5
WATER LEVEL SWITCH
CN3
YELLOW
CN2
BLACK
CN1
E
RED
RED
Y/G
1(L) 2(N) S
W
NOTE:
TO OUTDOOR UNIT
Please don't connect "W" if there
is no "W" terminal in outdoor unit.
T2
T1

Advertisement