www.eltra-trade.com
3. Fit M20 or ½" NPT cable glands for cables from bottom or sides of terminal box.
4. Mount earth wire in bottom of terminal box.
①
Connect electrode cable
②
Connect coil cable - keep separate from electrode cable
③
Connect power supply
④
Connect output cable
⑤
Connect PE (ground) wire
5. Mount connection plate in terminal box.
①
Electrode cable
②
Coil cable
③
Power supply
④
Output cable
6. Fit coil, electrode, supply and output cables through cable glands and connect to
connection plate as shown in Electrical connection (Page 36).
7. Fix connection plate with the two diagonally opposite screws.
info@eltra-trade.com
Installing/Mounting
4.4 Remote installation
27