Menu Structure - Siemens SITRANS F M MAG 5000 Manual

Hide thumbs Also See for SITRANS F M MAG 5000:
Table of Contents

Advertisement

Lock field symbols
Keypad
6.3
Operator menu
www.eltra-trade.com
Ready for change
Value locked
The keypad is used to set the flowmeter. The keys function as follows:
TOP UP KEY
FORWARD KEY
BACKWARD KEY
CHANGE KEY
SELECT KEY
LOCK/UNLOCK
KEY

Menu structure

The menu is built up of two parts. An operator menu and a setup menu, see also overview
diagrams MAG 5000/6000 and MAG 5000/6000 CT.
The operator menu is for daily operation. It is customized in the operator menu setup. The
transmitter always starts up in operator menu No. 1. The forward
are used to step through the operator menus.
Setup menu
The setup menu is for commissioning and service only. Access to the setup menu is gained
by pressing the top up key
● View mode
● Setup mode
View mode is a read-only mode. The pre-selected settings can only be scanned.
Access to submenu
RESET MODE: Zero setting of totalizers and
initialization of setting
This key (when held for 2 sec.) is used to switch between
operator menu and setup menu. In transmitter setup menu, a
short press will cause a return to previous level.
This key is used to step forward through the menus. It is the
only key normally used by the operator.
This key is used to step backwards through the menus.
With this key settings or numerical values are changed.
With this key figures to be changed are selected.
This key enables the operator to change settings and it gives
access to submenus.
for 2 seconds. The setup menu operates in two modes:
info@eltra-trade.com
Commissioning
6.3 Menu structure
and the backward keys
41
+421 552 601 099

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents