7.4

Output Timing Characteristics

4/9/2020
©2015-2020 FLIR
Integrated Imaging
Solutions Inc.
All rights reserved.
Output Timing Characteristics
Non-isolated Output Performance (measured at Vcc = 5 V, Rext = 1 kΩ)
Parameter
Output Low Voltage
Output High Voltage
Output Threshold High Voltage
Output Threshold Low Voltage
Cycle Rise Time
Cycle Fall Time
Opto Current
Opto-isolated Output Performance (measured at Vcc = 3.3 V, Rext = 200 Ω)
Parameter
Output Low Voltage
Output High Voltage
Output Threshold High Voltage
Output Threshold Low Voltage
Cycle Rise Time
Cycle Fall Time
Opto Current
Opto Isolator Delay (High to Low)
Opto Isolator Delay (Low to High)
Symbol
Non-isolated
V
0.23 V
L
V
4.95 V
H
V
4.48 V
THH
V
THL
t
R
t
0.23 μs
F
4.8 mA
Symbol
V
L
V
H
V
THH
V
THL
t
R
t
F
®
FLIR Oryx
Installation Guide
7 Input/Output Control
0.7 V
2.6 μs
Opto-isolated
Load
No Load
1.44 V
1.47 V
2.64 V
3.25 V
2.52 V
3.07 V
1.56 V
1.65 V
5.2 μs
24 μs
28 μs
4.6 μs
3.08 mA
8.4 mA
5.3 μs
5.5 μs
12.7 μs
15.2 μs
28