FLIR ORYX R Installation Manual page 31

Table of Contents

Advertisement

Parameter
Propagation Delay Low to High
Propagation Delay High to Low
Typical Positive Pulse Width
Typical Negative Pulse Width
4/9/2020
©2015-2020 FLIR
Integrated Imaging
Solutions Inc.
All rights reserved.
Opto-isolated Input Performance (Vcc = varying pk-pk)
Input Low Voltage
Input High Voltage
®
FLIR Oryx
Opto-isolated
Symbol
5 V, 1 kΩ
V
≤ 1.96 V
IL
V
≥ 2 V
IH
t
20.9 μs
PDLH
t
5.6 μs
PDHL
t
12 μs
MPPW
t
6 μs
MNPW
Installation Guide
7 Input/Output Control
Opto-isolated
3 V, 200 Ω
≤ 2 V
≥ 2.05 V
19.7 μs
16.7 μs
12 μs
6 μs