Mounting Your Oryx; Case Temperature And Heat Dissipation - FLIR ORYX R Installation Manual

Table of Contents

Advertisement

6.7

Mounting Your Oryx

Using the Case
The case is equipped with the following mounting holes:
Four (4) M4.0 x 0.7 mounting holes on each side of the case
n
One (1) 1/4-20 UNC mounting hole on the bottom of the case (standard and large case only)
n
6.8

Case Temperature and Heat Dissipation

You must provide sufficient heat dissipation to control the internal operating temperature of the camera.
The camera is equipped with an on-board temperature sensor. It allows you to obtain the temperature of the camera
board-level components. The sensor measures the ambient temperature within the case.
As a result of packing the camera electronics into a small space, the camera can become hot to the touch
when running. This is expected behavior and will not damage the camera electronics.
To reduce heat, use a cooling fan to set up a positive air flow around the camera, taking into consideration the following
precautions:
Mount the camera on a heat sink, such as a camera mounting bracket, made out of a heat-conductive material
n
like aluminum.
Make sure the flow of heat from the camera to the bracket is not blocked by a non-conductive material like
n
plastic.
Make sure the camera has enough open space around it to facilitate the free flow of air.
n
To access temperature information query the GenICam Device Control feature DeviceTemperature.