Download Print this page

Mitsubishi RV-2F-D Series Standard Specifications Manual page 119

Industrial robot

Advertisement

6 Safety
6.1 Safety
6.1.1 Self-diagnosis stop functions
No.
Function
Overload protection func -
1
tion
2
Overcurrent diagnosis
function
3
Encoder disconnection
diagnosis function
4
Deflection over diagnosis
function
5
AC power voltage drop
diagnosis function
CPU error detection func -
6
tion
7
Overrun
Software limit
prevention
detection
function
Mechanical
stopper
Stop
Operation
function
panel
Emergency
stop
Stop
Details
Activates when the total servo current time exceeds
the specified value.
Activates when an overcurrent flows to the motor
circuit.
Activates when the encoder cable is disconnected.
Activates when an error occurs between the com -
mand value and actual position, and the error
exceeds the specified amount.
Activates when the AC power voltage drops below
the specified value.
Activates when an error occurs in the CPU.
This is the limit provided by the software to enable
operation only in the operation range.
This is the mechanical stopper provided outside the
software.
Teaching
External
pendant
input
This is the stop with the highest degree of emergency. The servo power is shut off,
and the mechanical brakes (all axes) activate to stop the robot.
To recover, reset the alarm, and turn the servo ON with the servo ON command.
This is a stop operation with a high degree of emergency. The robot immediately
decelerates and stops.
Note that the servo power is not shut off. Use this when using the collision evasion
sensor, etc.
Remarks
The drive circuit is shut off. The robot stops, and
an alarm displays.
The drive circuit is shut off. The robot stops, and
an alarm displays.
The drive circuit is shut off. The robot stops, and
an alarm displays.
The drive circuit is shut off. The robot stops, and
an alarm displays.
The drive circuit is shut off. The robot stops, and
an alarm displays.
The drive circuit is shut off. The robot stops, and
an alarm displays.
The drive circuit is shut off. The robot stops, and
an alarm displays.
The robot mechanically stops, and function 1 or 2
activates.
Details
6Safety
Safety

Advertisement

loading

This manual is also suitable for:

Cr750-dCr751-d controller