Connecting The Cable - KSB Calio-Therm S NC/NCV Installation & Operating Manual

Circulating pump / high-efficiency drinking water pump
Table of Contents

Advertisement

Table 7: Cable dimensions
Cable dimensions
Outside diameter
Cross-section
2)
Fit wire end sleeves on stranded/flexible cables.
5 Installation at Site
NOTE
Connection to power supply must be effected by means of a fixed power cable with
a minimum cross-section of 3 × 1.5 mm
Connection to power supply must be effected by a power cable which is fitted with
an all-pole isolating switch with a minimum contact opening of 3 mm.
If the power cable of the device is damaged, have it replaced by the manufacturer,
a customer service technician or a similarly qualified person. See EN 60335-1.

5.6.1 Connecting the cable

Connecting the cable (Calio-Therm S NC/NCV S)
1. Verify the mains voltage at the site against the data on the name plate.
2. Switch off the power supply and make sure it cannot be switched on again
unintentionally.
3. Fit the union nut and joint ring on the cable.
4. Guide the cable through the plug housing until the cable ends are freely
accessible.
5. Strip the cable as shown in the following illustration.
Strip approx. 24 mm of the cable sheath and approx. 12 mm of the cores.
Fig. 5: Stripping the cable [mm]
6. Undo the cable gland. Guide the stripped cable through the cable gland.
Calio-Therm S NC/NCV
2
.
Values
5,5 - 10,0 mm
2
0,75 - 1,5 mm
(solid or stranded
2)
)