NOTE:
1 End any Emulation Control Interface or debugger sessions.
2 Disconnect the 50-pin cable from the emulation module, and plug
3 In the system window, click the emulation module and select

Solving Emulation Module Problems

Occasionally you may suspect a hardware problem with the emulation
module or target interface module. The procedures in this section
describe how to test the hardware, and if a problem is found, how to
repair or replace the broken component.
The emulation module uses the HP 16600A/16700A-series logic analysis
system's LAN interface. If you are having LAN-related problems with the
emulation module, refer to the logic analysis system's on-line help.
To run the performance verification tests using
the logic analysis system
the loopback test board (HP part number E3496-66502) into the
emulation module.
Performance Verification.
Chapter 6: Solving Problems
Solving Emulation Module Problems
143