Cannot access the pass-thru module serial console
interface using an RS232 connection from a PC
Terminal Emulation Program
Cause
The mini-USB to DB-9 RS232 cable is faulty. Try another mini-USB to DB-9 RS232 cable.
The connection settings do not match the
pass-thru module serial settings.
Error message appears on the serial console screen
that the pass-thru module failed to complete the
system self-test
Cause
The system diagnostic tests failed.
The keyboard locks up when you use HyperTerminal
to log in to the pass-thru module through the console
interface
Cause
Scroll lock is on.
Cannot connect to the pass-thru module console
interface remotely using Onboard Administrator
Cause
Flow control is enabled.
Action
Be sure that the PC Terminal Emulation session settings match
the pass-thru module serial settings.
Action
Note the reason for the failure and call a service representative.
Action
Press the Scroll Lock key on the keyboard and be sure that
the scroll lock is off.
Action
Disable flow control. Press Ctrl + Shift + _ to access the
Connect menu. When in the menu, enter C to change
settings, R for remote port settings, then N to disable flow
control.