Chapter 5: Using Debuggers
Using the Microtec Research Debugger
This will create the "msgfile" and log a summary of the messages that
occur between XRAY and the emulation probe/module to it. The
logging can be turned off with the following command:
PROBEMESSAGE OFF
To disconnect from the emulation probe/
module and target
In the Managers window, select the Connect tab. Click on the
emulation probe/module name that you want to disconnect. Under the
Control menu, select "Disconnect from Board" (or you can "Reconnect
to Board" if you have lost connection to the emulation probe/module).

Error conditions

"!ERROR 800! Invalid command: bcast"
This message usually means that there is no target interface probe/
module (TIM) connected to the emulation probe/module or the
emulation probe/module does not have firmware for the MPC500
family.
1. Verify that the emulation probe/module is connected to the target.
2. Next, check that your emulation probe/module is programmed with
firmware for the Motorola MPC500:
For an emulation probe, see "To display current firmware version
information" on page 40. If the emulation probe is not programmed with
the proper firmware, see "To update firmware for an emulation probe" on
page 40.
For an emulation module, see "To display current firmware version
information" on page 56. If the emulation module is not programmed with
the proper firmware, see "To update firmware using the Emulation Control
Interface" on page 56.